OWT-TC Thermocouple Temperature Signal Isolation Converter (17.5 mm)

The OWT-TC thermocouple temperature signal isolation converter adopts a digital MCU design. The thermocouple input type and temperature range can be changed via configuration software (AT2TC-Utility), offering both the flexibility of digital operation and the convenience of analog operation. It is primarily used for temperature measurement conversion and isolation.

This slim isolation converter provides two isolated signal outputs, and its switching power supply offers ease of installation. It also features power, input, and output indicator lights, as well as pluggable terminals for convenient on-site installation and monitoring of operating status.

OWT-TC Thermocouple Temperature Signal Isolation Converter (17.5 mm)

Features

Functional Specifications

Input Signal

CODE Measurement Range Input Impedance
K 0-1200°C 1MΩ
J 0-1000°C 1MΩ
E 0-1000°C 1MΩ
T -50-400°C 1MΩ
CODE Measurement Range Input Impedance
R 0-1600°C 1MΩ
S 0-1600°C 1MΩ
B 600-1800°C 1MΩ
N 0-1000°C 1MΩ

Accuracy: ≤ ±0.2% of FS

Cold joint compensation: ≤ ±0.5°C @ 0-60°C


Output signal (optional DIP switch to change the signal output range - option "DP")

Maximum output limit: 110% of full scale

Output Range Output Impedance Output Range (selected via a toggle switch on the PCB)
0-20mAdc ≤ 520Ω Output 1: lo (mA output - terminals 9+ & 8-)

Output 1: Vo (V output - terminals 7+ & 8-)

Output 2: lo (mA output - terminals 12+ & 11-)

Output 2: Vo (V output - terminals 10+ & 11-)
4-20mAdc ≤ 520Ω
0-10Vdc ≥ 1000Ω
2-10Vdc ≥ 1000Ω
0-5Vdc ≥ 500Ω
1-5Vdc ≥ 500Ω
Standard products: Please specify the output signal range in the specification selection table when ordering.

Response time: ≤ 100ms (input 10%-90% of FS)

Output ripple: ≤ ±0.1% of FS

Full-scale calibration range: ≤ ±5% of FS, 2 outputs can be individually adjusted.

Zero-point correction range: ≤ ±5% of FS, 2 sets of outputs can be adjusted individually.

Model Specifications

OWT-TC - Output Circuit - Input Type - Temperature Range - Output Signal 1 / Output Signal 2 - Operating Power Supply - (Optional Function)

CODE Output Circuit
1 1 set of outputs
2 2 set of outputs
K J E T R S B N CODE Input Temperature Range
A -50-100°C
B 0-50°C
C 0-100°C
D 0-200°C
E 0-400°C
F 0-500°C
G 0-600°C
H 0-800°C
I 0-1000°C
J 0-1200°C
K 0-1600°C
L 600-1800°C
T Settable range

CODE Output Signal Range
N None
C 0-20 mA
D 4-20 mA
3 0-5V
4 0-10V
5 1-5V
6 2-10V
If you choose to purchase one output type, please enter "N" in column 2 of the output signal field.
CODE Working Power Supply
ADH AC 85-264V
DC 100-300V
ADL AC/DC 20-56V
CODE Selection Function
DP Output signal switching switch

OWT-CABLE (optional)

OWT-TC-Utility software data cable